مشخصات پژوهش

صفحه نخست /Electrochemical Behavior ...
عنوان
Electrochemical Behavior and Voltammetric Determination of Diclofenac at a Multi-Walled Carbon Nanotube-Ionic Liquid Composite Modified Carbon Ceramic Electrode
نوع پژوهش مقاله چاپ شده
کلیدواژه‌ها
Carbon nanotube; Diclofenac; Ionic liquid; Modified electrode
چکیده
This work describes the electrochemical behavior of diclofenac on the surface of a carbonceramic electrode (CCE) modified with multi-walled carbon nanotubes (MWCNT) and an ionic liquid (IL) composite. The MWCNT-IL composite showed an enhancement effect in the electro-oxidation of diclofenac with respect to a bare carbon ceramic electrode. Based on the experimental outcomes, a possible mechanism for the electro-oxidation of diclofenac is proposed and discussed. Under the optimized experimental conditions, the MWCNT-IL CCE showed a linear response to diclofenac over the concentration range 50 nM–20 lM with a detection limit of 27 nM. The developed diclofenac sensor showed good stability, sensitivity, and reproducibility in the measurement of diclofenac in human blood plasma samples.
پژوهشگران حبیب رزمی (نفر اول)، کیانوش سرهنگ زاده (نفر دوم)، رحیم محمدرضائی (نفر سوم)